Smoke Test Application
WARNING: This page is about a different variant/trim than selected.
- Ignition Off.
- Place the air filter in a disposable plastic bag and secure it in the air cleaner housing to help prevent smoke leakage.
- Remove a B193 Charge Air Cooler Temperature Sensor, refer to Charge Air Cooler Air Temperature Sensor Replacement .
- Connect the GE 41413-A hose to the GE 41413-311 .
- Insert the GE 41413-311 into the Charge Air Cooler (CAC) temperature sensor mounting boss on the CAC inlet or outlet duct.
- Apply smoke continuously with the GE 41413-A while moving all duct work, pipes, and tubes.
- Verify smoke is not visible at the components listed below:
- Mass air flow sensor
- Air cleaner outlet duct
- Turbocharger air inlet adapter
- Crankcase depression regulator valve
- Intake manifold and gaskets
- Charge Air Cooler Hoses/Pipes/Tubes
- If smoke is visible
Repair or replace the affected gasket, seal or component as necessary and repeat steps 6 and 7.
- Go to next step: If smoke is not visible
- Refer to Component/System Leak Test and perform the Charge Air Cooler Diagnosis (Induction System Air Leak Test).
NOTE:
Wrap the GE 41413-311 with a layer of electrical tape to protect the threads in the inlet/outlet duct.
NOTE:
To improve the visibility of the smoke exiting the engine, illuminate the suspected leak area with the GE 41413-SPT and observe the area from different angles.