Conditions for Running the DTC
P118B
- DTC P16D7, P16D8, P16D9, P24D0, P262B, U02A3 = Not set
- DTCs related to the following system/component = Not Set
- B17 Barometric Pressure Sensor
- B131 Exhaust Temperature Sensor
- No other DTCs related to the concerned component are set.
- Barometric Pressure = Greater than 70 kPa (10.2 PSI)
- Ignition Off Time = For greater than 8 h
- Ignition = On
- Ignition and Start Switch Signal = Greater than 11 V
- Reductant Control Module Relays 1 and 2 = On
Frequency the DTC runs = Continuously - After the running conditions are met
P1474, P1475, P1476, P147B, P24B1, P24B3, P24B5, P24B6, P24C8, P24C9
- DTC P16D7, P16D8, P16D9, P24D0, U02A3 = Not set
- No other DTCs related to the concerned component are set.
- Ignition = On
- Ignition and Start Switch Signal = Greater than 11 V
- { P147B } - Particulate Matter Sensor Temperature = 200 to 392°C (425 to 797°F)
- Reductant Control Module Relays 1 and 2 = On
Frequency the DTC runs = Continuously - After the running conditions are met - For greater than 1.5 s
P24AF
- DTC P16D7, P16D8, P16D9, P24D0, U02A3 = Not set
- No other DTCs related to the concerned component are set.
- Ignition = On
- Ignition and Start Switch Signal = Greater than 11 V
- Reductant Control Module Relays 1 and 2 = On
Frequency the DTC runs = Continuously - After the running conditions are met - For greater than 2 min
P24B0
- DTC P16D7, P16D8, P16D9, P24D0, U02A3 = Not set
- No other DTCs related to the concerned component are set.
- Ignition = On
- Ignition and Start Switch Signal = Greater than 11 V
- Particulate Matter Sensor Temperature = 560 to 800°C (1, 040 to 1, 472°F)
- Reductant Control Module Relays 1 and 2 = On
Frequency the DTC runs = Continuously - After the running conditions are met
P24B4
- DTC P16D7, P16D8, P16D9, P24D0, P262B, U02A3 = Not set
- DTCs related to the following system/component = Not Set
- B34 Engine Coolant Temperature Sensor
- B65 Intake Manifold Pressure and Air Temperature Sensor
- B75C Multifunction Intake Air Sensor
- B115 Vehicle Speed Sensor
- No other DTCs related to the concerned component are set.
- Ambient Air Temperature = Warmer than -12°C (10°F)
- Ignition = On
- Ignition and Start Switch Signal = Greater than 11 V
- Reductant Control Module Relays 1 and 2 = On
Frequency the DTC runs = Continuously - After the running conditions are met
P24C7
- DTC P16D7, P16D8, P16D9, P24D0, P262B, U02A3 = Not set
- DTCs related to the following system/component = Not Set
- B17 Barometric Pressure Sensor
- B34 Engine Coolant Temperature Sensor
- B65 Intake Manifold Pressure and Air Temperature Sensor
- B75C Multifunction Intake Air Sensor
- B131 Exhaust Temperature Sensor
- No other DTCs related to the concerned component are set.
- Ambient Air Temperature = Warmer than -40°C (-40°F)
- Barometric Pressure = Greater than 60 kPa (8.7 PSI)
- Engine = Running
- Ignition = On
- Ignition and Start Switch Signal = Greater than 11 V
- Particulate Matter Sensor Operation = Allowed - For greater than 5 s
- Reductant Control Module Relays 1 and 2 = On
Frequency the DTC runs = Continuously - After the running conditions are met - For greater than 25.5 s
P24D1
- DTC P16D7, P16D8, P16D9, P24D0, U02A3 = Not set
- DTCs related to the following system/component = Not Set
- B17 Barometric Pressure Sensor
- B131 Exhaust Temperature Sensor
- No other DTCs related to the concerned component are set.
- Ignition = On
- Ignition and Start Switch Signal = Greater than 11 V
- Reductant Control Module Relays 1 and 2 = On
Frequency the DTC runs = Continuously - After the running conditions are met
P24DA
- DTC P16D7, P16D8, P16D9, P24D0, P262B, U02A3 = Not set
- DTCs related to the following system/component = Not Set
- B17 Barometric Pressure Sensor
- B131 Exhaust Temperature Sensor
- No other DTCs related to the concerned component are set.
- Barometric Pressure = Greater than 70 kPa (10.2 PSI)
- Engine = Running
- Ignition = Off - For greater than 8 h
- Ignition and Start Switch Signal = Greater than 11 V
- Particulate Matter Sensor Operation = Allowed - For greater than 5 s
- Particulate Matter Sensor Temperature = -20 to 200°C (-4 to 392°F)
- Reductant Control Module Relays 1 and 2 = On
Frequency the DTC runs = Continuously - After the running conditions are met
U04A4
- Ignition = On
- Ignition and Start Switch Signal = Greater than 11 V
Frequency the DTC runs = Continuously - After the running conditions are met