Removal Procedure
WARNING: This page is about a different variant/trim than selected.
- Drain the cooling system. Cooling System Draining and Filling (Static LM2) , or Cooling System Draining and Filling (GE 47716 LM2)
- Plenum Front Panel Outer Reinforcement - Remove - Plenum Front Panel Outer Reinforcement Removal and Installation
Remove wiring harness nut and reposition harness and retainers as needed.
- Remove the heater inlet hose bracket attached to the exhaust gas recirculation valve.
Engine Wiring Harness Bracket Nut (2) - Remove [3x]
- Disconnect the electrical connectors and detach retainers as needed.
- Engine Wiring Harness (3) - Reposition
Exhaust Pressure Differential Sensor Bracket Stud (1) - Remove [2x]
- Exhaust Pressure Differential Sensor Bracket (2) - Reposition
Exhaust Pressure Sensor Hose Clamp (1) @ Exhaust Pressure Differential Sensor Pipe - Disengage - Hose Clamp Replacement Guidelines - Spring Type
- Remove the exhaust pressure differential sensor hose from the exhaust gas recirculation pipe.
Exhaust Gas Recirculation Pipe Nut (1) - Remove
- NOTE:
The clamp is part of the pipe and single use.
Exhaust Gas Recirculation Pipe Nut (1) - Remove
Exhaust Gas Recirculation Valve Hose (1) - Remove
- Exhaust Gas Recirculation Outlet Pipe Gasket (2) - Remove and DISCARD
- Exhaust Gas Recirculation Valve Vacuum Hose Clamp (3) - Remove and DISCARD
Disconnect the electrical connector (1).
- Exhaust Gas Recirculation Pipe Bolt (2) - Remove [2x]
Exhaust Gas Recirculation Pipe Bolt (1) - Remove [2x]
Exhaust Gas Recirculation Valve (1) - Remove
- Exhaust Gas Recirculation Valve Cooler Gasket (2) - Remove and DISCARD