Installation Procedure
Emission Reduction Fluid Tank Filler Vent Hose (2) - Install
- Emission Reduction Fluid Tank Filler Vent Hose (2) - Connect - Plastic Collar Quick Connect Fitting Service
- Retainer (1) - Engage
Emission Reduction Fluid Controller (2) - Install
- Emission Reduction Fluid Controller Bolt (1) - Install and tighten [2x] - Fastener Specifications
- Connect the emission reduction fluid tank reservoir wire harness at controller.
- Support the emission reduction fluid tank with a suitable jack.
Emission Reduction Fluid Tank (1) - Install
Emission Reduction Fluid Tank Protector Bolt (1) - Install and tighten - Fastener Specifications
Emission Reduction Fluid Tank Protector Bolt (1) - Install and tighten - Fastener Specifications
Emission Reduction Fluid Tank Bolt (1) - Install and tighten [2x] - Fastener Specifications
- Remove the suitable jack.
Electrical Connector (1) - Connect
Emission Reduction Fluid Tank Filler Hose (1) - Connect [2x] - Plastic Collar Quick Connect Fitting Service
Emission Reduction Fluid Tank Shield (2) - Install
- Emission Reduction Fluid Tank Protector Bolt (1) - Install and tighten [4x] - Fastener Specifications
Emission Reduction Fluid Exhaust Front Pipe Injector Supply Pipe (2) - Install
- Retainer (3) - Install
- Emission Reduction Fluid Exhaust Front Pipe Injector Supply Pipe (2) - Connect - Plastic Collar Quick Connect Fitting Service
- Electrical Connector (1) - Connect
Emission Reduction Fluid Tank Protector (2) - Install
- Retainer (1) - Install
Emission Reduction Fluid Tank Heat Shield (1) - Install
Emission Reduction Fluid Tank Heat Shield Retainer (1) - Install [2x]
Emission Reduction Fluid Tank Heat Shield Retainer (1) - Install [4x]
- Lower the vehicle.
- Prime the system. Emission Reduction Fluid Pump Priming
- Refill the emission reduction fluid tank.
- Perform the nitrogen oxide catalytic converter reductant loading reset. Nitrogen Oxides Catalytic Converter Reductant Loading Reset
- Perform the reductant fluid tank level reset. Reductant Fluid Tank Level Reset
Refer to Fastener Caution .
Refer to Fastener Caution .