Installation Procedure
WARNING: This page is about a different variant/trim than selected.
Transfer Case Control Module (1) - Install
- Transfer Case Control Module Bracket Nut (2) - Install and tighten [2x] - Fastener Specifications
Position and connect the body harness connector (2).
- Connect the transfer case control module electrical connector (1).
- Connect the battery negative cable. Battery Negative Cable Disconnection and Connection (9C1, 5W4) , or Battery Negative Cable Disconnection and Connection (KL9)
- Perform the K69 transfer case control module programming and setup. K69 Transfer Case Control Module: Programming and Setup
CAUTION:
Refer to Fastener Caution .