Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
C05FB 12
Range Actuator Position Sensor = Greater than 4.7 V
C05FB 11
Range Actuator Position Sensor = Less than 0.5 V
C05FB 13
- Range Actuator Position Sensor = 0 Hz
- Range Actuator Position Sensor = 2.38 to 3.49 V
C05FB 29
Range Actuator Position Sensor = Greater than 5 Hz
C05FB 38
Range Actuator Position Sensor = Greater than 2000 Hz
C11B9 12
Range Actuator Position Sensor Direction Signal = Greater than 4.731 V
C11B9 11
Range Actuator Position Sensor Direction Signal = Less than 0.53 V
C11B9 13
- Range Actuator Position Sensor Direction Signal = 0 Hz
- Range Actuator Position Sensor Direction Signal = 2.38 to 3.49 V
C11B9 38
Range Actuator Position Sensor Direction Signal = Greater than 2000 Hz
C15AB 12
Range Actuator Position Sensor Supply Voltage = Greater than 5.21 V
C15AB 11
Range Actuator Position Sensor Supply Voltage = Less than 4.76 V
C15AB 13
Condition 1
- Range Actuator Position Sensor = 0 Hz
- Range Actuator Position Sensor = 0.944 to 2.3792 V
Condition 2
- Range Actuator Position Sensor Direction Signal = 0 Hz
- Range Actuator Position Sensor Direction Signal = 0.944 to 2.3792 V
C15C1 13
Condition 1
- Range Actuator Position Sensor = 0 Hz
- Range Actuator Position Sensor = 4.1296 to 4.729 V
Condition 2
- Range Actuator Position Sensor Direction Signal = 0 Hz
- Range Actuator Position Sensor Direction Signal = 4.1296 to 4.729 V