K218 Front Suspension Leveling/Lifting Hydraulic Power Pack Module (E60)
Courtesy of GENERAL MOTORS COMPANY
|
Connector Part Information
- Harness Type:Crossbody Front Wiring Harness
- OEM Connector: 31380-1100
- Service Connector: Service by Harness - See Part Catalog
- Description: 38-Way F 0.64, 2.8, 6.3 Series, Sealed
|
Terminal Part Information
| Terminal Type ID |
Terminated Lead |
Diagnostic Test Probe |
Terminal Removal Tool |
| I |
Not required |
J-35616-42 (RD) |
No Tool Required |
| I |
Not required |
J-35616-42 (RD) |
No Tool Required |
| II |
Not required |
J-35616-4A (PU) |
No Tool Required |
| III |
Not required |
J-35616-64B (L-BU) |
No Tool Required |
| Pin |
Size |
Color |
Circuit |
Function |
Terminal Type ID |
Option |
| 1 |
2.5 |
RD/WH |
140 |
Battery Positive Voltage |
I |
- |
| 2 |
- |
- |
- |
Not Occupied |
- |
- |
| 3 |
- |
BK/GY |
11883 |
Right Front Strut Displacement Sensor Low Reference |
I |
- |
| 4 - 5 |
- |
- |
- |
Not Occupied |
- |
- |
| 6 |
- |
BN/RD |
11882 |
Right Front Strut Displacement Sensor Voltage Reference |
I |
- |
| 7 |
0.35 |
BU |
4987 |
AUTOSAR CAN Bus [+] 1 Serial Data |
III |
- |
| 8 |
0.35 |
WH |
4986 |
AUTOSAR CAN Bus [-] 1 Serial Data |
III |
- |
| 9 |
- |
BN/WH |
11878 |
Left Front Strut Displacement Sensor Signal |
I |
- |
| 10 |
- |
YE/WH |
11884 |
Right Front Strut Displacement Sensor Signal |
I |
- |
| 11 |
- |
- |
- |
Not Occupied |
- |
- |
| 12 |
0.35 |
YE/BK |
6121 |
Air Suspension Mode Switch Signal |
III |
- |
| 13 |
2.5 |
BK |
3050 |
Ground |
I |
- |
| 14 |
- |
BK/BU |
11877 |
Left Front Strut Displacement Sensor Low Reference |
I |
- |
| 15 - 16 |
- |
- |
- |
Not Occupied |
- |
- |
| 17 |
- |
BU/RD |
11876 |
Left Front Strut Displacement Sensor Voltage Reference |
I |
- |
| 18 |
- |
- |
- |
Not Occupied |
- |
- |
| 19 |
0.35 |
BU |
4987 |
AUTOSAR CAN Bus [+] 1 Serial Data |
III |
- |
| 20 |
0.35 |
WH |
4986 |
AUTOSAR CAN Bus [-] 1 Serial Data |
III |
- |
| 21 - 24 |
- |
- |
- |
Not Occupied |
- |
- |
| 25 |
0.35 |
RD/GY |
8540 |
Battery Positive Voltage |
II |
- |
| 26 - 37 |
- |
- |
- |
Not Occupied |
- |
- |
| 38 |
0.35 |
BK |
3050 |
Ground |
II |
- |