Home >> Chevrolet >> 2022 >> Camaro LS, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 30 (Engine Controls And Fuel - 6.2L (LT1/LT4) - Diagnostic Information And Procedures (3 Of 3)) >> Diagnostic Information and Procedures >> DTC P10E1-P10E4 >> Typical Scan Tool Data

Typical Scan Tool Data

WARNING: This page is about a different variant/trim than selected.
Ignition On/Start Circuit Source Bypass Relay Control Circuit High Voltage Test Status

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition = On & KR171 Engine Control Module Wake-Up Relay = On
Parameter Normal Range:  OK or Not Run
B+ - Relay Coil OK or Not Run OK or Not Run OK or Not Run
Control - Relay Coil OK or Not Run OK or Not Run Malfunction
Ignition On/Start Circuit Source Bypass Relay Control Circuit Low Voltage Test Status

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition = On
Parameter Normal Range:  OK or Not Run
B+ - Relay Coil Malfunction OK or Not Run OK or Not Run
Control - Relay Coil Malfunction OK or Not Run OK or Not Run
Ignition On/Start Circuit Source Bypass Relay Control Circuit Open Test Status

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition = On
Parameter Normal Range:  OK or Not Run
B+ - Relay Coil OK or Not Run Malfunction OK or Not Run
Control - Relay Coil OK or Not Run Malfunction OK or Not Run