Component Testing
WARNING: This page is about a different variant/trim than selected.
- Remove the component:
- Transmission Fluid Pan
- Control Valve Body
- Disconnect the appropriate electrical connector: Q77 Transmission Control Solenoid Valve
- Test for the resistance listed below between the test points: Terminal 1@Q77 Transmission Control Solenoid Valve & Terminal 2@Q77 Transmission Control Solenoid Valve
- Transmission Control Solenoid Valve 1 - 6 = 5.0 to 5.4 ohms
- Transmission Control Solenoid Valve 9 = 18 to 22 ohms
- If not the specified value
Replace the appropriate component: Q77 Transmission Control Solenoid Valve
- Go to next step: If the specified value
- Test for infinite resistance between the test points: Terminal 1@Q77 Transmission Control Solenoid Valve & The component's housing
- If less than infinite resistance
Replace the appropriate component: Q77 Transmission Control Solenoid Valve
- If less than infinite resistance
NOTE:
The component's temperature should be 19 to 21°C (66 to 70°F) while testing.