Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P0716
Input Speed Sensor = Decreases greater than 1999 RPM - For greater than 7.5 s
P0717
Input Speed Sensor = Less than 169 RPM - For greater than 4 s
P07BF
Input Speed Sensor = Less than 0.25 V/Short to Ground - For greater than 1 s
P07C0
Input Speed Sensor = Greater than 4.75 V/Short to Voltage - For greater than 1 s
P1783 Condition 1
Current Gear = Forward Gear & Input Shaft Speed Sensor Direction = Reverse - For greater than 2.5 s
Condition 2
Current Gear = Reverse Gear & Input Shaft Speed Sensor Direction = Forward - For greater than 2.5 s
P17CE