Conditions for Setting the DTC
P0182, P0187
Fuel Rail Temperature Sensor 1, 2 = Less than a predefined threshold - For greater than 4 s
P0183, P0188
Fuel Rail Temperature Sensor 1, 2 = Greater than a predefined threshold - For greater than 4 s
P0191
Fuel Rail Pressure Sensor 2 = Greater than a predefined threshold - For greater than 2.6 s
P0192
Fuel Rail Pressure Sensor 2 = Greater than a predefined threshold - For greater than 2.6 s
P111F
The following parameters are not within 10°C (18°F) of each other:
- Fuel Rail Temperature Sensor 1
- Fuel Rail Temperature Sensor 2
The above condition(s) must occur for greater than 8 s.
P126E, P126F
Fuel Rail Temperature Sensor 1, 2 = Greater than the maximum threshold - For greater than 4 s
P127C
Fuel Rail Pressure Sensor 2 = Greater than a predefined threshold - For greater than 2.6 s
P128A, P128B
Fuel Rail Temperature Sensor 1, 2 = Greater than a predefined threshold - For greater than 2.6 s
P16E4, P16E5
Serial data message from component: B310 Fuel Pressure/Temperature Sensor = Not Received - For greater than 3.25 s