Circuit/System Verification
- Verify that no other DTCs are set.
- If any DTCs are set
- Go to next step: If no DTCs are set
- Ensure the battery charge cord is not connected.
- Vehicle ON.
- Verify with a scan tool, the hybrid/EV powertrain control module High Voltage Circuit and the battery energy control module Hybrid/EV Battery Pack Terminal 1 Voltage are within 16 V of each other and DTC P0AF8 did not reset.
- If the parameters are not within 16 V of each other or DTC P0AF8 is set
Refer to Circuit/System Testing, Battery Main Bus Diagnostics.
- Go to next step: If the parameters are within 16 V of each other and DTC P0AF8 is not set
- If the parameters are not within 16 V of each other or DTC P0AF8 is set
- Connect the battery charge cord.
- Verify with a scan tool, the hybrid/EV powertrain control module 2 Battery Charger High Output and the battery energy control module Hybrid Battery Pack Terminal 1 Voltage are within 16 V of each other and DTC P0AF8 did not reset.
- If the parameters are not within 16 V of each other or DTC P0AF8 is set
Refer to Circuit/System Testing, Battery Charger Bus Diagnostics.
- Go to next step: If the parameters are within 16 V of each other and DTC P0AF8 is not set
- If the parameters are not within 16 V of each other or DTC P0AF8 is set
- All OK
NOTE:
The contactors must be closed.