Circuit/System Description
The high voltage hybrid/EV battery contains 288 individual cells. Three cells are welded together in parallel and called a cell group. There are a total of 96 cell groups in the hybrid/EV battery assembly. These cell groups are electrically connected in series. Each individual cell group is rated at 3.65 V, for a nominal system voltage of 350 V direct current. The battery cell groups are electrically joined to form 10 distinct electrical modules.
The battery energy control module monitors the voltage of the 96 battery cell groups. The voltage sense lines are attached to each individual cell group, and these sense lines terminate at connectors located on the side of the battery cell module. A voltage sense harness joins this connector to the battery energy control module.
The battery energy control module will determine when a fault condition is present. Diagnostics and system status are communicated from the battery energy control module to the hybrid powertrain control module 2 through serial data. The hybrid powertrain control module 2 is the host controller for diagnostic trouble code information.