Home >> Chevrolet >> 2021 >> Trailblazer RS, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (Engine Controls And Fuel - 1.0L (L4B L4F L4G LIJ) Or 1.2L (L4H L4K LIF LIH) - Diagnostic Information And Procedures (1 Of 2)) >> Diagnostic Information and Procedures >> DTC P0182, P0183, P0187, P0188, P0191, P0192, P111F, P126E, P126F, P127C, P128A, P128B, U0625, U0670, U0671, or U101B >> Conditions for Setting the DTC

Conditions for Setting the DTC

WARNING: This page is about a different variant/trim than selected.

P0182 

Fuel Temperature Sensor 1 = Greater than a predefined threshold - For greater than 1.2 s

P0183 

Fuel Temperature Sensor 2 = Greater than a predefined threshold - For greater than 1.2 s

P0187 

Fuel Rail Temperature Sensor 1 = Greater than a predefined threshold - For greater than 1.2 s

P0188 

Fuel Rail Temperature Sensor 2 = Greater than a predefined threshold - For greater than 1.2 s

P0191 

The difference between the following parameters is greater than a predefined value: Fuel Rail Pressure Sensor 1 Performance Fuel Rail Pressure Sensor 2 Performance - For greater than 1.5 s

P0192 

Fuel Rail Pressure Sensor 1 = Less than a predefined threshold - For greater than 1.25 s

P111F 

The following parameters are not within 15°C (59°F) of each other:

The above condition(s) must occur for greater than 1 s.

P126E 

Fuel Rail Temperature Sensor 1 = Greater than the maximum threshold - For greater than 1.2 s

P126F 

Fuel Rail Temperature Sensor 2 = Greater than the maximum threshold - For greater than 1.2 s

P127C 

Fuel Rail Pressure Sensor 2 = Greater than a predefined threshold - For greater than 1.2 s

P128A 

Fuel Rail Pressure Sensor 1 = Greater than a predefined threshold - For greater than 1.2 s

P128B 

Fuel Rail Pressure Sensor 2 = Greater than a predefined threshold - For greater than 1.2 s

U0625 

Fuel Rail Pressure Sensor 1 = No Communication Detected - For greater than 2.6 s

U0670 

Fuel Temperature Sensor 1 = No Communication Detected - For greater than 2.6 s

U0671 

Fuel Temperature Sensor 2 = No Communication Detected - For greater than 2.6 s

U101B 

Fuel Rail Pressure Sensor 2 = No Communication Detected - For greater than 2.6 s