Transmission Fluid Pump Assemble
WARNING: This page is about a different variant/trim than selected.
Forward Clutch Housing Fluid Seal Ring Assemble
| Callout | Component Name |
|---|---|
| 1 | Forward Clutch Housing Fluid Seal Ring [2x] Procedure Install NEW seals. Do NOT reuse old seals. |
| 2 | Forward Clutch Housing Fluid Seal Ring [2x] Procedure Install NEW seals. Do NOT reuse old seals. |
Automatic Transmission Fluid Pump Body Assemble
| Callout | Component Name |
|---|---|
| 1 | Auxiliary Control Valve Body Spacer Plate |
| 2 | Automatic Transmission Fluid Pump Thrust Plate |
| 3 | Automatic Transmission Fluid Pump Cam |
| 4 | Automatic Transmission Fluid Pump Shaft |
| 5 | Automatic Transmission Fluid Pump Pressure Plate |
| 6 | Automatic Transmission Fluid Pump Pressure Plate Seal Procedure Install NEW seals. Do NOT reuse old seals. Install seal in fluid pump pressure plate. |
| 7 | Automatic Transmission Fluid Pump Pressure Plate Seal Procedure Install NEW seals. Do NOT reuse old seals. Install seal in fluid pump body. |
| 8 | Automatic Transmission Fluid Pump Body |
| 9 | Line Blowoff Ball Valve |
| 10 | Line Blowoff Ball Valve Spring |
| 11 | Line Blowoff Ball Valve Spring Retainer |
| 12 | Automatic Transmission Fluid Pump Cover Bolt [7x] M6 x 65
CAUTION:
Refer to Fastener Caution . Tighten 10 N.m (89 lb in) |
| 13 | Automatic Transmission Fluid Pump Cover Bolt [2x] M6 x 30 Tighten 10 N.m (89 lb in) |
Automatic Transmission Auxiliary Fluid Pump Assemble
| Callout | Component Name |
|---|---|
| 1 | Automatic Transmission Auxiliary Fluid Pump Seal Procedure Install NEW seals. Do NOT reuse old seals. |
| 2 | Automatic Transmission Auxiliary Fluid Pump |
| 3 | Automatic Transmission Auxiliary Fluid Pump Bolt M5 x 50 Tighten 4.7 N.m (42 lb in) |
| 4 | Automatic Transmission Auxiliary Fluid Pump Bolt [3x] M5 x 33 Tighten 4.7 N.m (42 lb in) |
Drive Link, Drive Sprocket, and Driven Sprocket Assemble
| Callout | Component Name |
|---|---|
| 1 | Torque Converter Fluid Seal Ring
CAUTION:
Do not use old seal rings. Install NEW seal rings. Reusing old seal rings may cause internal transmission leaks and transmission damage.
CAUTION:
Size the fluid seal rings for at least 5 minutes after installation to obtain proper seal ring size. Failure to do so may cause internal transmission leaks and transmission damage. Procedure Use the seal pusher and sizer from DT-51191 Pump Seal Installer Set along with the DT-51191-4 Stator Shaft Seal Protector to install the torque converter fluid seal ring. Special Tools
Equivalent regional tools: Special Tools |
| 2 | Drive Sprocket Thrust Washer |
| 3 | Drive Sprocket |
| 4 | Driven Sprocket |
| 5 | Drive Link |
| 6 | Driven Sprocket Retaining Ring Procedure Install a NEW retaining ring. Do NOT reuse the old retaining ring. |
| 7 | Automatic Transmission Fluid Baffle |
Automatic Transmission Fluid Filter Assemble
| Callout | Component Name |
|---|---|
| 1 | Automatic Transmission Fluid Filter Procedure Install a NEW filter. DO NOT reuse old filter. |
| 2 | Automatic Transmission Auxiliary Fluid Pump Bolt M5 x 20 Tighten 4.7 N.m (42 lb in) |