Circuit/System Verification
- Ignition ON.
- Verify the scan tool Fuel Remaining in Tank parameter is between 5 - 95% and varies with fuel level.
- If not between 5 - 95% or does not vary with fuel level
Refer to Circuit/System Testing.
- Go to next step: If between 5 - 95% and varies with fuel level
- If not between 5 - 95% or does not vary with fuel level
- Verify that all fuel level gauge segments illuminate when performing the scan tool Fuel Gauge Sweep control function commanded to 80%.
- If any fuel level gauge segments do not illuminate
Replace the P16 Instrument Cluster.
- Go to next step: If all fuel level gauge segments illuminate
- If any fuel level gauge segments do not illuminate
- All OK.