Diagnostic Fault Information
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| B+ - Terminal 8 @ T19 Power Supply Transformer | 3 | 3 | - | - |
| B+ - Terminal 11 @ T19 Power Supply Transformer | 3 | 3 | - | - |
| B+ - Terminal 9 @ T19 Power Supply Transformer | 3 | 3 | 3 | - |
| B+ - Terminal 10 @ T19 Power Supply Transformer | 3 | 3 | 3 | - |
| Ignition Voltage - Terminal 4 @ T19 Power Supply Transformer | 3 | 3 | - | - |
| Ignition Voltage - Terminal 6 @ T19 Power Supply Transformer | 3 | 3 | - | - |
| Signal - Terminal 12 X1 @ K9 Body Control Module | 1 | 1 | 1 | P15A3 00 |
| Control - Terminal 5 X1 @ K9 Body Control Module | 2 | 2 | 2 | - |
| Control - Terminal 15 X5 @ K9 Body Control Module | - | 2 | 2 | - |
| Control - Terminal 5 @ T19 Power Supply Transformer | 3 | 3 | - | - |
| Ground Terminal 1 @ S124 Stop/Start Select Switch | - | 1 | - | - |
| Ground - Terminal 7 @ T19 Power Supply Transformer | - | 3 | - | - |
| Ground - Terminal 12 @ T19 Power Supply Transformer | - | 3 | - | - |
| 1 Stop/Start Select Switch - Malfunction 2 Stop/Start Select Switch Indicator - Malfunction 3 Radio - Malfunction |
||||