Conditions for Setting the DTC
P058A
The B110 Battery Monitor Module detects an internal fault.
P058B
The B110 Battery Monitor Module detects an internal fault after comparing an induced 50 μA current to the Battery Monitor Module calculated current.
P058C
The B110 Battery Monitor Module detects a difference between raw temperature values to be 10° C (50.0° F) for more for 8 out of 10 samples.
P058D
An absolute difference of 5.00 V or more is detected between the 12 V system reference voltage measured by the ECM, and 12 V battery voltage measured by the B110 Battery Monitor Module for 32 out of 40 samples.
P058E
The B110 Battery Monitor Module detects a raw temperature 2 value of 120° C (248.0° F) or more for 4 out of 5 samples.
P058F
The B110 Battery Monitor Module detects a raw temperature 2 value of -43° C (-45.4° F) or less for 4 out of 5 samples.