Circuit/System Verification
- Ignition - On / Vehicle - In Service Mode
- Verify the scan tool parameter: Ambient Air Temperature = -40 to 88° C (-40 to 190° F) and changes
- If not between -40 and 88° C (-40 and 190° F) or does not change
Refer to: Circuit/System Testing
- Go to next step: If between -40 and 88° C (-40 and 190° F) and changes
- If not between -40 and 88° C (-40 and 190° F) or does not change
- Perform the special tool function: Ambient Air Temperature Instant Update
- Verify the following parameter is within 5° C (8° F) of the actual ambient air temperature: Ambient Air Temperature
- If not within 5° C (8° F) of the actual ambient air temperature
Refer to: Circuit/System Testing
- Go to next step: If within 5° C (8° F) of the actual ambient air temperature
- If not within 5° C (8° F) of the actual ambient air temperature
- All OK.