Component Testing
- Ignition/Vehicle - Off
- Disconnect the electrical connector: B280 Automatic Transmission Accumulator Solenoid Valve
- Test for 16 to 20 Ω between the test points: Control terminal 2 & Ignition terminal 1
- If not between 16 and 20 Ω
Replace the component: Automatic Transmission Auxiliary Fluid Accumulator
- Go to next step: If between 16 and 20 Ω
- If not between 16 and 20 Ω
- Test for infinite resistance between the test points: Each terminal of the component & The component's housing
- If less than infinite resistance
Replace the component: Automatic Transmission Auxiliary Fluid Accumulator
- Go to next step: If infinite resistance
- If less than infinite resistance
- All OK.