Conditions for Setting the DTC
P1467
EVAP Purge Pump Speed & Desired EVAP Purge Pump Speed = Not within a calibrated range - For greater than 5 s
P1468
EVAP Purge Pump Speed = Greater than 240 RPM @ Commanded Off - For greater than 5 s
P1469
EVAP Purge Pump Speed = Less than -100 RPM - For greater than 5 s
P146A
EVAP Purge Pump Speed = Greater than 55000 RPM - For greater than 5 s
P148E
EVAP Purge Pump Voltage = Less than 3.5 V - For greater than 1 s
P148F
EVAP Purge Pump Voltage = Greater than 28.0 V - For greater than 1 s
P1490
EVAP Purge Pump Voltage & Ignition Voltage = Not within 2.0 V of each other - For greater than 1 s
P14A4
EVAP Purge Pump - Temperature = Greater than a predefined threshold - For greater than 8 s
U111E
Serial data message from component: G58 Evaporative Emission Purge Pump = Not Received - For greater than 1 s