Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle & All vehicle systems - Off
- Disconnect the electrical connector: @ K111 Fuel Pump Driver Control Module
- Test for less than 10 ohms between the test points: Ground circuit terminal 22 & Ground
- If 10 ohms or greater
- Disconnect the ground connection: Ground terminal
- Test for less than 2 ohms between the test points: Ground circuit terminal 22 @ Component harness & The other end of the circuit @ Ground terminal
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Repair the open/high resistance in the ground connection.
- Go to next step: If less than 10 ohms
- Verify a test lamp turns On between the test points: B+ circuit terminal 7 & Ground
- If the test lamp does not turn On and the circuit fuse is OK
- Remove - Test Lamp
- Test for less than 2 ohms between the test points: B+ circuit terminal 7 @ Control module harness & Output terminal @ F35RA Fuse
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Verify the fuse is OK and there is voltage at the fuse.
- If the test lamp does not turn On and the circuit fuse is open
- Remove - Test Lamp
- Test for infinite resistance between the test points: Ignition circuit terminal 17 @ Control module harness & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance - Replace the component: K111 Fuel Pump Driver Control Module
- Go to next step: If the test lamp turns On
- Ignition - On / Vehicle - In Service Mode
- Verify a test lamp turns On between the test points: Ignition circuit terminal 17 & Ground
- If the test lamp does not turn On and the circuit fuse is OK
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for less than 2 ohms between the test points: Ignition circuit terminal 17 @ Control module harness & Output terminal @ F50UA Fuse
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Verify the fuse is OK and there is voltage at the fuse.
- If the test lamp does not turn On and the circuit fuse is open
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for infinite resistance between the test points: Ignition circuit terminal 17 @ Control module harness & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance - Replace the component: K111 Fuel Pump Driver Control Module
- Go to next step: If the test lamp turns On
- Replace the component: K111 Fuel Pump Driver Control Module
NOTE:
Some control module ground circuits may require up to 2 min after the ignition is turned Off before achieving a resistance reading of less than 5 ohms. In most cases the readings will drop below 20 ohms within 1 min indicating the control modules are going to sleep.