Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle & All vehicle systems - Off
- Disconnect the electrical connector: Q13 Evaporative Emission Vent Solenoid Valve
- Ignition - On / Vehicle - In Service Mode
- Verify a test lamp turns On between the test points: B+ circuit terminal 2/B & Ground
- If the test lamp does not turn On and the circuit fuse is OK
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for less than 2 ohms between the test points: B+ circuit terminal 2/B & Output terminal @ Fuse
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Verify the fuse is OK and there is voltage at the fuse.
- If the test lamp does not turn On and the circuit fuse is open
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for infinite resistance between the test points: B+ circuit terminal 2/B & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance - Replace the component: Q13 Evaporative Emission Vent Solenoid Valve
- Go to next step: If the test lamp turns On
- Verify a test lamp does not turn On between the test points: Control circuit terminal 1/A & B+
- If the test lamp turns On
- Ignition/Vehicle - Off & Remove - Test lamp
- Disconnect the electrical connector: K111 Fuel Pump Driver Control Module
- Test for infinite resistance between the test points: Control circuit terminal 1/A @ Component harness & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance - Replace the component: K111 Fuel Pump Driver Control Module
- Go to next step: If the test lamp does not turn On
- Remove - Test Lamp
- Perform the scan tool control function: EVAP Vent Solenoid Valve - Not Venting
Verify the scan tool parameter: EVAP Vent Solenoid Valve Control Circuit High Voltage Test Status = OK
- If not the specified state
- Ignition/Vehicle - Off
- Disconnect the electrical connector: K111 Fuel Pump Driver Control Module
- Ignition - On / Vehicle - In Service Mode
- Test for less than 1 V between the test points: Control circuit terminal 1/A @ Component harness & Ground
- If 1 V or greater - Repair the short to voltage on the circuit.
- If less than 1 V - Replace the component: K111 Fuel Pump Driver Control Module
- Go to next step: If the specified state
- Connect a 3 A fused jumper wire between the test points: Control circuit terminal 1/A & B+ circuit terminal 2/B
- Perform the scan tool control function: EVAP Vent Solenoid Valve - Not Venting
Verify the scan tool parameter: EVAP Vent Solenoid Valve Control Circuit High Voltage Test Status = Malfunction
- If not the specified state
- Ignition/Vehicle - Off & Remove - Jumper wire(s)
- Disconnect the electrical connector: K111 Fuel Pump Driver Control Module
- Test for less than 2 ohms between the test points: Control circuit terminal 1/A @ Component harness & The other end of the circuit @ Control module harness
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Replace the component: K111 Fuel Pump Driver Control Module
- Go to next step: If the specified state
- Test or replace the component: Q13 Evaporative Emission Vent Solenoid Valve