Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P0097
NOTE:
The scan tool display range is between -40 and 150°C (-40 and 302°F).
IAT Sensor 2 = Colder than -60°C (-76°F) For greater than 4 s
P0098
IAT Sensor 2 = Warmer than 150°C (302°F) - For greater than 4 s
P0099
IAT Sensor 2 = Signal noisy or erratic - For greater than 4 s
P00F4
Intake Air Humidity Sensor = Less than 6% - For greater than 4 s
P00F5
Intake Air Humidity Sensor = Greater than 106% - For greater than 4 s
P00F6
Intake Air Humidity Sensor = Signal noisy or erratic - For greater than 4 s
P0112
IAT Sensor 1 = Colder than -60°C (-76°F) - For greater than 4 s
P0113
IAT Sensor 1 = Warmer than 149°C (300°F) - For greater than 4 s
P0114
IAT Sensor 1 = Signal noisy or erratic - For greater than 4 s