LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2021 >> Blazer RS, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 10 (Engine Controls And Fuel - 2.0L (LSY) - Diagnostic Information And Procedures (1 Of 2)) >> Diagnostic Information and Procedures >> DTC P0033-P0035 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different variant/trim than selected.
  1. Ignition/Vehicle & All vehicle systems - Off
  2. Disconnect the electrical connector: Q40 Turbocharger Bypass Solenoid Valve
  3. Ignition - On/Vehicle - In Service Mode
  4. Verify a test lamp turns On between the test points: Ignition circuit terminal 1 & Ground
    • If the test lamp does not turn On and the circuit fuse is OK 
    1. Ignition/Vehicle - Off & Remove - Test lamp
    2. Test for less than 2 ohms between the test points: Ignition circuit terminal 1 & Output terminal @ Fuse
      • If 2 ohms or greater - Repair the open/high resistance in the circuit.
      • If less than 2 ohms - Verify the fuse is OK and there is voltage at the fuse.
    • If the test lamp does not turn On and the circuit fuse is open 
    1. Ignition/Vehicle - Off
    2. Replace the component: Fuse
    3. Ignition - On/Vehicle - In Service Mode
    4. Verify the fuse does not open.
      • If the fuse opens and there are components connected to the circuit - Disconnect a component and repeat procedure starting at step 4.1
      • If the fuse opens with all components disconnected from the circuit - Repair the short to ground on the circuit.
      • If the fuse does not open after disconnecting a component from the circuit - Replace the component disconnected last.
    • Go to next step: If the test lamp turns On 
  5. Verify a test lamp does not turn On between the test points: Control circuit terminal 2 & Ignition circuit terminal 1
    • If the test lamp turns On 
    1. Ignition/Vehicle - Off & Remove - Test lamp
    2. Test for infinite resistance between the test points: Control circuit terminal 2 @ Component harness & Ground
      • If less than infinite resistance - Repair the short to ground on the circuit.
      • If infinite resistance - Replace the component: K20 Engine Control Module
    • Go to next step: If the test lamp does not turn On 
  6. Perform the scan tool control function: Turbocharger Bypass Solenoid Valve - Active

    Verify a test lamp turns On between the test points: Control circuit terminal 2 & Ignition circuit terminal 1

    • If the test lamp does not turn On 
    1. Ignition/Vehicle - Off & Remove - Test lamp
    2. Disconnect the electrical connector: X3 @ K20 Engine Control Module
    3. Ignition - On/Vehicle - In Service Mode
    4. Test for less than 1 V between the test points: Control circuit terminal 2 @ Component harness & Ground
      • If 1 V or greater - Repair the short to voltage on the circuit.
      • Go to next step: If less than 1 V
    5. Ignition/Vehicle & All vehicle systems - Off
    6. Test for less than 2 ohms between the test points: Control circuit terminal 2 @ Component harness & The other end of the circuit
      • If 2 ohms or greater - Repair the open/high resistance in the circuit.
      • If less than 2 ohms - Replace the component: K20 Engine Control Module
    • Go to next step: If the test lamp turns On 
  7. Test or replace the component: Q40 Turbocharger Bypass Solenoid Valve