Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle & All vehicle systems - Off
- Disconnect the electrical connector: Q40 Turbocharger Bypass Solenoid Valve
- Ignition - On/Vehicle - In Service Mode
- Verify a test lamp turns On between the test points: Ignition circuit terminal 1 & Ground
- If the test lamp does not turn On and the circuit fuse is OK
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for less than 2 ohms between the test points: Ignition circuit terminal 1 & Output terminal @ Fuse
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Verify the fuse is OK and there is voltage at the fuse.
- If the test lamp does not turn On and the circuit fuse is open
- Ignition/Vehicle - Off
- Replace the component: Fuse
- Ignition - On/Vehicle - In Service Mode
- Verify the fuse does not open.
- If the fuse opens and there are components connected to the circuit - Disconnect a component and repeat procedure starting at step 4.1
- If the fuse opens with all components disconnected from the circuit - Repair the short to ground on the circuit.
- If the fuse does not open after disconnecting a component from the circuit - Replace the component disconnected last.
- Go to next step: If the test lamp turns On
- Verify a test lamp does not turn On between the test points: Control circuit terminal 2 & Ignition circuit terminal 1
- If the test lamp turns On
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for infinite resistance between the test points: Control circuit terminal 2 @ Component harness & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance - Replace the component: K20 Engine Control Module
- Go to next step: If the test lamp does not turn On
- Perform the scan tool control function: Turbocharger Bypass Solenoid Valve - Active
Verify a test lamp turns On between the test points: Control circuit terminal 2 & Ignition circuit terminal 1
- If the test lamp does not turn On
- Ignition/Vehicle - Off & Remove - Test lamp
- Disconnect the electrical connector: X3 @ K20 Engine Control Module
- Ignition - On/Vehicle - In Service Mode
- Test for less than 1 V between the test points: Control circuit terminal 2 @ Component harness & Ground
- If 1 V or greater - Repair the short to voltage on the circuit.
- Go to next step: If less than 1 V
- Ignition/Vehicle & All vehicle systems - Off
- Test for less than 2 ohms between the test points: Control circuit terminal 2 @ Component harness & The other end of the circuit
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Replace the component: K20 Engine Control Module
- Go to next step: If the test lamp turns On
- Test or replace the component: Q40 Turbocharger Bypass Solenoid Valve