Circuit/System Verification
- Ignition ON.
- Verify the DTC P0461, P0462, P0463, or P0464 are not set
- If DTC P0461, P0462, P0463, or P0464 are set
Refer to Circuit/System Testing
- Go to next step: If DTC P0461, P0462, P0463, and P0464 are not set
- If DTC P0461, P0462, P0463, or P0464 are set
- If equipped, verify the fuel level gauge needle sweeps when performing the scan tool Instrument Cluster Gauge Sweep control function.
- If the fuel level gauge does not sweep
Replace the P16 Instrument Cluster
- Go to next step: If the fuel level gauge sweeps
- If the fuel level gauge does not sweep
- Verify the low fuel level indicator turns ON and OFF when commanding the scan tool All Indicators control function ON and OFF.
- If the low fuel level indicator does not turn ON and OFF
Replace the P16 Instrument Cluster
- Go to next step: If the low fuel level indicator turns ON and OFF
- If the low fuel level indicator does not turn ON and OFF
- Verify the scan tool Fuel Level Sensor parameter is between 0.5 - 3.5 V and varies with fuel level.
- If not between 0.5 - 3.5 V or does not vary with fuel level
Refer to Circuit/System Testing
- Go to next step: If between 0.5 - 3.5 V and varies with fuel level
- If not between 0.5 - 3.5 V or does not vary with fuel level
- All OK.