Conditions for Setting the DTC
DTC P0D69
A/C compressor motor voltage is greater than 30 V.
DTC P0D6A
The A/C compressor high voltage input sensor value is greater than 527.25 V for 1 second.
DTC P0D6B
The A/C compressor high voltage input sensor value is less than 27.75 V for 1 second.
DTC P0D71
The A/C compressor processor temperature sensor value is greater than 30°C (86°F).
AND
The difference between the A/C compressor processor temperature sensor value and the outside air temperature value is greater than 22°C (72°F).
DTC P0D72
A/C compressor processor temperature sensor value is less than -40°C (-40°F) for 6 seconds.
DTC P0D73
A/C compressor processor temperature sensor value is greater than 150°C (302°F) for 6 seconds.
DTC P0D76
The A/C compressor temperature sensor value is greater than 30°C (86°F).
AND
The difference between the A/C compressor temperature sensor value and the outside air temperature value is greater than 22°C (72°F).
DTC P0D77
A/C compressor temperature sensor value is less than -40°C (-40°F) for 6 seconds.
DTC P0D78
A/C compressor temperature sensor value is greater than 150°C (302°F) for 6 seconds.