LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2020 >> Malibu LS >> Repair and Diagnosis >> External Pages >> Different car >> Section 99 (HVAC - Automatic) >> Diagnostic Information and Procedures >> DTC B393B >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2019 Chevrolet Malibu. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition/Vehicle - Off
  2. Disconnect the electrical connector: Q46 A/C Compressor Solenoid Valve
  3. Connect a test lamp between the test points: Control circuit terminal 1 & Control circuit terminal 2
  4. Ignition - On / Vehicle - In Service Mode
  5. Perform the scan tool control function:A/C Compressor Solenoid Valve

    Verify the test lamp state:

    A/C Compressor Solenoid Valve - Off = Test lamp Off

    A/C Compressor Solenoid Valve - On = Test lamp On

    • If not the specified state 
    1. Ignition/Vehicle - Off & Remove - Test lamp
    2. Disconnect the electrical connector: K33 HVAC Control Module
    3. Ignition - On / Vehicle - In Service Mode
    4. Test for less than 1 V between the test points:
      • Control circuit terminal 1 @ Component harness & Ground
      • Control circuit terminal 2 @ Component harness & Ground
      • If 1 V or greater - Repair the short to voltage on the circuit.
      • Go to next step: If less than 1 V
    5. Ignition/Vehicle - Off
    6. Test for infinite resistance between the test points:
      • Control circuit terminal 1 @ Component harness & Ground
      • Control circuit terminal 2 @ Component harness & Ground
      • If less than infinite resistance - Repair the short to ground on the circuit.
      • Go to next step: If infinite resistance
    7. Test for less than 2 ohms between the test points:
      • Control circuit terminal 1 @ Component harness & Terminal 10 @ Control module harness
      • Control circuit terminal 2 @ Component harness & Terminal 11 @ Control module harness
        • If 2 ohms or greater - Repair the open/high resistance in the circuit.
        • If less than 2 ohms - Replace the component: K33 HVAC Control Module
    • Go to next step: If the specified state 
  6. Test or replace the component: Q46 A/C Compressor Solenoid Valve