Hood Ajar Operation - Starter/Generator Control Module (with RPO HP6)
WARNING: This page is about a different car, the 2019 Chevrolet Malibu. However, it is still accessible from the selected car via links, so may be relevant.
The starter/generator control module applies B+ to the hood ajar signal circuit and monitors the voltage to determine the position of the hood. The hood ajar switch contains a multiplexed resistor. This resistor will vary the voltage seen by the starter/generator control module by pulling down the applied voltage based on the position of the switch.