Typical Scan Tool Data
WARNING: This page is about a different car, the 2019 Chevrolet Malibu. However, it is still accessible from the selected car via links, so may be relevant.
HO2S 1, 2
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage |
|---|---|---|---|
Operating Conditions:
Parameter Normal Range: 200 to 800 mV |
|||
| Signal - Terminal 4 | 0 V | 1.7 to 2.1 V | 1.7 to 2.1 V |
| Signal - Terminal 3 | 0 V | 1.7 to 2.1 V | 1.7 to 2.1 V |