LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2020 >> Malibu LS >> Repair and Diagnosis >> External Pages >> Different car >> Section 115 (Automatic Transmission - VT40 (MRG) - Repair Instructions - Off Vehicle) >> Repair Instructions - Off Vehicle >> Control Valve Body Assembly Installation

Control Valve Body Assembly Installation

WARNING: This page is about a different car, the 2019 Chevrolet Malibu. However, it is still accessible from the selected car via links, so may be relevant.
GM4738284Courtesy of GENERAL MOTORS COMPANY
Control Valve Body Installation

Callout Component Name
1 Control Valve Body Locating Pin [2x]
2 Control Valve Body

Procedure

  1. Install control valve body on case.
  2. Align the manual shift detent lever in the groove of the manual valve.
3 Valve Body Bolt [2x] M5 x 55
CAUTION:

Refer to Fastener Caution .


Tighten 
8 N.m (71 lb in)
GM4738269Courtesy of GENERAL MOTORS COMPANY
Control Valve Solenoid Body Installation

Callout Component Name
1 Control Valve Solenoid Body
2 Automatic Transmission Fluid Pressure Sensor Seal [2x]
Procedure 
Install a NEW seal. Do NOT reuse the old seal.
3 Automatic Transmission Fluid Pressure Sensor [2x]
4 Valve Body Bolt [7x] M5 x 70
Procedure 
Hand tighten and follow torque sequence below.
5 Valve Body Bolt [7x] M5 x 100
Procedure 
Hand tighten and follow torque sequence below.
6 Valve Body Bolt [11x] M5 x 85
Procedure 
Hand tighten and follow torque sequence below.
7 Valve Body Bolt [2x] M5 x 98.3
Procedure 
Hand tighten and follow torque sequence below.
GM4944928Courtesy of GENERAL MOTORS COMPANY
Control Valve Solenoid Body Torque Sequence

Callout Component Name
1 Valve Body Bolt [7x] M5 x 70
Tighten in sequence 
8 N.m (71 lb in)
2 Valve Body Bolt [7x] M5 x 100
Tighten in sequence 
8 N.m (71 lb in)
3 Valve Body Bolt [11x] M5 x 85
Tighten in sequence 
8 N.m (71 lb in)
4 Valve Body Bolt [2x] M5 x 98.3
Tighten in sequence 
8 N.m (71 lb in)
GM4694198Courtesy of GENERAL MOTORS COMPANY
Automatic Transmission Wiring Harness Installation

Callout Component Name
1 Automatic Transmission Fluid Temperature Sensor Seal
Procedure 
Install a NEW seal. Do NOT reuse the old seal.
2 Automatic Transmission Wiring Harness
Procedure
  1. Install the wiring harness.
  2. Connect the harness connectors.
  3. Slide connector lock as indicated by arrow.
3 Wiring Harness Connector Bolt [2x] M5 x 25
Tighten 
8 N.m (71 lb in)
4 Wiring Harness Connector Bolt M5 x 20
Tighten 
8 N.m (71 lb in)