Component Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector : B130 Exhaust Gas Recirculation Temperature Sensor
- Test the resistance between the test points : Signal terminal 2 & Low Reference terminal 1
- Verify the value is within the range listed in the table : Temperature Versus Resistance - Exhaust Gas Temperature Sensor
- If not in the specified range
Replace the component : B130 Exhaust Gas Recirculation Temperature Sensor
- Go to next step : If in the specified range
- If not in the specified range
- Test for infinite resistance between the test points : Each terminal of the component & The component's housing
- If less than infinite resistance
Replace the component : B130 Exhaust Gas Recirculation Temperature Sensor
- Go to next step : If infinite resistance
- If less than infinite resistance
- All OK.
NOTE:
Use the special tool : EL-25070 Heat Gun 260 to 400°C (500 to 750°F)