Circuit/System Description
Ignition 3 voltage is supplied to the mode switch from the blower motor switch. The blower motor switch must be in any position except for OFF for A/C operation. The mode switch must be in one of the following positions for an A/C request:
- MAX A/C
- A/C
- Bi- Level
- Defog
- Defrost
Once the mode switch is in one of these positions, the mode switch applies ignition 3 voltage to the A/C high pressure switch. If the A/C high pressure switch is closed, the voltage will then be applied to the powertrain control module (PCM), for the 8.1L (RPO L18), or engine control module (ECM), for the 6.6L (RPO LLY). The voltage applied to the ECM/PCM is an A/C request signal. The PCM/ECM then monitors the voltage on the A/C low pressure switch signal. If the voltage is low near ground, then the ECM/PCM will enable the A/C compressor clutch relay. The ECM/PCM provides a ground for the relay so it can close it internal contacts.