Installation Procedure
Air Conditioning Evaporator and Blower Module (1) - Install
- CAUTION:
Refer to Fastener Caution .
Air Conditioning Evaporator and Blower Module Nut (1) - Install and tighten [2x] 5.5 N.m (49 lb in)
Air Conditioning Evaporator and Blower Module Nut (1) - Install and tighten 5.5 N.m (49 lb in)
Air Conditioning Evaporator and Blower Module Nut (1) - Install and tighten [2x] 5.5 N.m (49 lb in)
Air Conditioning Evaporator and Blower Module Nut (1) - Install and tighten [2x] 5.5 N.m (49 lb in)
Connect the air inlet valve actuator vacuum hose (1).
Install the right side floor front air outlet center duct (2). Floor Front Air Outlet Center Duct Replacement - Right Side
Engine Cover (1) - Install - Engine Cover Replacement
Front Floor Console Extension Panel (2) - Install - Front Floor Console Extension Panel Replacement
Air Conditioning Evaporator (1) - Install
Blower Case Assembly (1) - Install - Blower Case Replacement
Air Conditioning Accumulator (2) @ Air Conditioning Evaporator - Install - Air Conditioning Accumulator Replacement
- Air Conditioning Evaporator Tube (1) @ Air Conditioning Evaporator - Install - Air Conditioning Evaporator Tube Replacement (C60) , or Air Conditioning Evaporator Tube Replacement (C69)
Coolant Recovery Reservoir (1) - Install - Coolant Recovery Reservoir Replacement (LV1) , or Coolant Recovery Reservoir Replacement (L96, LC8)
- Evacuate and charge the refrigerant system. Refrigerant Recovery and Recharging
- Visually inspect for air conditioning system refrigerant leaks.