Diagnostic Aid
The following diagnostic aids apply for both current and history DTCs.
An incorrectly installed CPA or incorrectly seated connector can cause a shorting bar to short both control circuits together. Check the connectors and CPAs if a DTC with symptom byte 02 or 0E is set, to ensure the shorting bars are not causing the circuits to be shorted together. Shorting bars are used in the locations listed below:
- Passenger instrument panel air bag
- Driver and passenger seat side air bags
- Left and right roof rail air bags
- Driver and passenger seat belt buckle pretensioners
- Inline connectors - on the side of the harness connector
- Harness side of the K36 Inflatable Restraint Sensing and Diagnostic Module connector
Terminal fretting or incorrectly seated connectors can cause an open/high resistance condition. Check the circuit terminals for fretting or incorrectly seated connector if a DTC with symptom byte 04 or 0D is set. If DTCs of deployment loops which are in the seat DTC B0014 and B0021, can occur because of stress or damage to the harness due to seat movement. Move the seat to the full extend of travel while using the scan tool to observe deployment type loop parameters.