Circuit/System Description
The BCM 3 fuse, located in the underhood fuse block, supplies battery voltage to the body control module (BCM). The BCM applies this voltage to the courtesy lamps through the courtesy lamp supply voltage circuit. When any door is opened, the door open switch contacts close and the BCM receives a door-open input. If the BCM receives a door lock or unlock input, the BCM will activate the courtesy lamp supply voltage circuit, providing battery voltage to the dome lamp and instrument panel (I/P) courtesy lamps. The courtesy lamps can be manually activated by placing the interior lamp switch in the DOME position.
Inadvertent power courtesy lamp feature provides a similar function for the interior lamps as a retained accessory power feature. The BCM will energize the courtesy lamps supply voltage circuit when the BCM is in the active state (awake). When the inadvertent power courtesy lamps supply voltage circuit is energized, it supplies voltage from the BCM 2 fuse located in the underhood fuse block, to all the interior lights listed below. The BCM will continue to supply voltage to the interior lamps after the ignition is turned OFF so that the interior lamps may be operated.
- Front Dome/Reading Lamp
- Middle Dome/Reading Lamp
- Rear Dome/Reading Lamp
- Sunshade Mirror Lamps
- Underhood Lamp
In the event that any of these lamps were to remain illuminated for a period of more than 20 minutes with the ignition switch in the OFF position and no BCM input activity, the BCM will deactivate the inadvertent power supply voltage circuit to prevent a total battery discharge condition.