X101 Front Fascia Harness to Forward Lamp Harness (BOP+T3U-T3N)
Connector Part Information
|
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | Not Required | J-35616-2A (GY) | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| II | Not Required | J-35616-3 (GY) | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| Pin | Size | Color | Circuit | Terminal Type ID | Option | Function | Pin | Size | Color | Circuit | Terminal Type ID | Option |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 0.5 | BU/GY | 636 | I | BOP+UGM+T3U | Ambient Air Temperature Sensor Signal Ambient Air Temperature Sensor Signal |
1 | 0.35 | BU/GY | 636 | II | BOP+UGM+T3U |
| 2 | 0.5 | BK/BU | 61 | I | BOP+UGM+T3U | Ambient Air Temperature Sensor Low Reference Ambient Air Temperature Sensor Low Reference |
2 | 0.35 | BK/BU | 61 | II | BOP+UGM+T3U |
| 3 | 0.5 | BN/VT | 2234 | I | BOP+T3U | Front Fog Lamp Control 2 Front Fog Lamp Control 2 |
3 | 0.5 | BN/VT | 2234 | II | BOP+T3U |
| 4 | 0.5 | BK | 1750 | I | BOP+T3U | Ground 17 Ground 17 |
4 | 0.5 | BK | 1750 | II | BOP+T3U |
| 5 | 0.5 | GN/BK | 2738 | I | BOP+UGM+T3U | Virtual Key Module LIN Bus 1 Virtual Key Module LIN Bus 1 |
5 | 0.5 | GN/BK | 2738 | II | BOP+UGM+T3U |
| 6 | 0.5 | RD/BN | 2940 | I | BOP+UGM+T3U | Secondary Fused Battery Positive Voltage 29 Secondary Fused Battery Positive Voltage 29 |
6 | 0.5 | RD/BN | 2940 | II | BOP+UGM+T3U |
| 7 | 0.5 | BK | 1450 | I | BOP+UGM+T3U | Ground 14 Ground 14 |
7 | 0.5 | BK | 1450 | II | BOP+UGM+T3U |
| 8 | - | - | - | - | - | Not Occupied | 8 | - | - | - | - | - |