Circuit/System Testing
NOTE:
Circuit/System Verification must be performed before proceeding with Circuit/System Testing.
- Ignition OFF, disconnect the harness connector at the secondary fuel level sensor.
- Ignition ON, verify that the scan tool Fuel Tank Level Remaining parameter display is less than 4 percent.
- If greater than the specified value, test the secondary signal circuit terminal 4 for a short to ground. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the secondary fuel level sensor.