K33 HVAC Control Module (C41/C60)
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | 13575571 | J-35616-64B (LT BU) | J-38125-553 | Not Available | Not Available | Not Available | Not Available |
| II | 13582288 | J-35616-64B (LT BU) | J-38125-553 | Not Available | Not Available | Not Available | Not Available |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 0.5 | RD/GN | 3140 | Battery Positive Voltage | I | - |
| 2 | 0.35 0.35 |
BU/WH VT/BN |
292 741 |
Rear Defog Switch Signal Run Ignition 3 Voltage |
II II |
C41 C60 |
| 3 | 0.35 0.35 |
GN/WH BN/BU |
4115 683 |
Local Interconnect Network Serial Data Bus 15 Rear Defog Indicator Control |
II II |
C60+KL9 C60-KL9 |
| 4 | 0.35 0.35 |
WH BN/YE |
6816 762 |
Indicator Dimming Control A/C Request Signal |
II II |
C41 C60 |
| 5 | 0.35 0.35 |
YE WH/BN |
6817 2212 |
LED Backlight Dimming Control Auxiliary A/C Request Indicator Signal |
II II |
C60+KL9 C60-KL9 |
| 6 | 0.35 | YE | 6817 | LED Backlight Dimming Control | II | C60-KL9 |
| 7 | 0.35 0.35 |
VT BN/BU |
272 683 |
Defrost Control Signal Rear Defog Indicator Control |
II II |
C41 C60-KL9 |
| 8 | 0.5 | BK | 1050 | Ground | I | - |
| 9 | 0.35 | GY/RD | 598 | 5V Reference | II | - |
| 10 | 0.35 | VT/GN | 1838 | Recirculation Door Position Signal | II | - |
| 11 | 0.35 | BK/YE | 1791 | Air Temperature Door Control Low Reference | II | - |
| 12 | 0.35 | GN | 1614 | Recirculation Door Control | II | - |
| 13 | 0.35 | YE/BK | 2274 | Recirculation Door Control | II | - |
| 14 - 16 | - | - | - | Not Occupied | - | - |