LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2019 >> Spark ACTIV, Standard Trans >> Repair and Diagnosis >> Engine Mechanical >> Mechanical >> Engine Mechanical - 1.0L (L5Q) Or 1.4L (LV7) - Repair Instructions - Off Vehicle >> Repair Instructions - Off Vehicle >> Piston, Connecting Rod, and Bearing Cleaning and Inspection >> Connecting Rod Cleaning Procedure

Connecting Rod Cleaning Procedure

  1. Clean the connecting rods in solvent.
  2. WARNING:

    Refer to Safety Glasses Warning .

  3. Dry the connecting rod using compressed air.
  4. Remove the connecting rod cap and clean the threads.
  5. Remove the connecting rod bearing and discard. Never reuse a connecting rod bearing used in a running engine.