| 1 |
Lower Crankcase Procedure
- Ensure proper use of room temperature vulcanizing (RTV) sealant. Use of Room Temperature Vulcanizing (RTV) and Anaerobic Sealant
NOTE:
- All sealing surfaces must be free of contamination prior to applying the sealer.
- Installation and final torque specification must be completed within 10 minutes of applying the sealant.
- Apply a 3 mm bead of sealer directly in the groove of the block to bedplate mating surfaces. Refer to Adhesives, Fluids, Lubricants, and Sealers (Europe LV7)
, or Adhesives, Fluids, Lubricants, and Sealers (Europe L5Q)
, or Adhesives, Fluids, Lubricants, and Sealers (North America LV7)
, or Adhesives, Fluids, Lubricants, and Sealers (North America L5Q)
.
- Install the lower crankcase, ensure the lower crankcase is aligned properly on the dowels. Tap gently into place with a suitable tool, if necessary.
|
| 2 |
Lower Crankcase Bolt[10x]
Procedure Tighten the NEW lower crankcase bolts in the sequence shown.
- Tighten the bolts in sequence a first pass to 15 N. m (11 lb ft).
- Using the EN 45059
angle meter, tighten the bolts in sequence a final pass to 180 degrees.
Special Tools EN-45059
Angle Meter For equivalent regional tools, refer to Special Tools
. |
| 3 |
Lower Crankcase Bolt [13x] Procedure
- Apply sealant to the lower crankcase perimeter bolts. Refer to Adhesives, Fluids, Lubricants, and Sealers (Europe LV7)
, or Adhesives, Fluids, Lubricants, and Sealers (Europe L5Q)
, or Adhesives, Fluids, Lubricants, and Sealers (North America LV7)
, or Adhesives, Fluids, Lubricants, and Sealers (North America L5Q)
.
- Tighten the lower crankcase bolts in the sequence shown.
- Tighten the bolts in sequence a first pass to 5 N. m (44 lb in).
- Tighten the bolts in sequence a final pass to 10 N. m (89 lb in).
|