Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P206B
The reductant control module detects the reductant quality sensor has an internal short or open circuit condition for a distance travelled greater than 1.5 km (1 mi) for greater than 1 s.
P206D
The reductant control module detects that the reductant quality sensor signal is out of range high for a distance travelled greater than 1.5 km (1 mi) for greater than 2 s.
P2B9A