LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2019 >> Cruze Premier, 4D Hatchback >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 7 (Engine Controls And Fuel - 1.6L (LH7) Diesel - Diagnostic Information And Procedures (P057B-P208D)) >> Diagnostic Information and Procedures >> DTC P10D9, P10DE, P10DF, P10E0, P10EF, P10F0-P10F3, P20B9-P20BF, P20C0, P214F, P21DD, P221C, or P221D (68 Body - Hatchback) >> Conditions for Setting the DTC

Conditions for Setting the DTC

WARNING: This page is about a different variant/trim than selected.

P10D9 

The ECM indicates the reductant tank heater 1 low control circuit is shorted to the high control circuit for greater than 1 s.

P10DE 

The ECM indicated the reductant tank heater high control voltage circuit is open for greater than 1 s.

P10DF 

The ECM indicated the reductant tank heater high control circuit is shorted to ground for greater than 1 s.

P10E0 

The ECM indicated the reductant tank heater high control circuit is shorted to voltage for greater than 1 s.

P10EF 

The ECM indicated the reductant tank heater 1 low side driver internal circuit is open for greater than 1 s.

P10F0 

The ECM indicated the reductant tank heater 1 low side driver internal control is shorted to ground or overloaded for greater than 1 s.

P10F1 

The ECM indicated the reductant tank heater 2 low side driver internal circuit is open for greater than 1 s.

P10F2 

The ECM indicated the reductant tank heater 2 low side driver internal circuit is shorted to ground or overloaded for greater than 1 s.

P10F3 

The ECM indicates the reductant tank heater 2 low control circuit is shorted to the high control circuit for greater than 1 s.

P20B9 

The ECM indicates the reductant tank heater low control circuit is open for greater than 1 s.

P20BA 

The ECM indicates the reductant tank heater power is greater or less than a calibrated value for greater than 10 s.

P20BB 

The ECM indicates the reductant tank heater low control circuit is shorted to ground for greater than 1 s.

P20BC 

The ECM indicates the reductant tank heater low control circuit is shorted to voltage for greater than 1 s.

P20BD 

The ECM indicates the reductant line heater low control circuit is open for greater than 1 s.

P20BE 

The ECM indicates the reductant line heater power is greater or less than a calibrated value for greater than 10 s.

P20BF 

The ECM indicates the reductant line heater low control circuit is shorted to ground or overloaded for greater than 1 s.

P20C0 

The ECM indicates the reductant line heater low control circuit is shorted to voltage for greater than 1 s.

P214F 

The ECM indicates the reductant tank heater 2 voltage is greater than a calibrated value for greater than 8 s.

P21DD 

The ECM indicates the reductant tank heater 2 voltage is less than a calibrated value for greater than 6 s.

P221C 

The ECM indicates the reductant line heater 2 voltage is less than a calibrated value for greater than 6 s.

P221D 

The ECM indicates the reductant line heater 2 voltage is greater than a calibrated value for greater than 6 s.