Conditions for Running the DTC
WARNING: This page is about a different variant/trim than selected.
P176B
- Battery Voltage = Greater than 9 V
- Engine = Running
- Run/Crank Ignition 1 Voltage = Greater than 9 V
- Transmission Input Speed = Greater than 172 RPM
- Transmission Output Speed = Greater than 89 RPM
Frequency the DTC runs = Continuously - After the running conditions are met
P176C, P176D, P17D3
- Battery Voltage = Greater than 9 V
- Power Mode Status = Run
- Run/Crank Ignition 1 Voltage = Greater than 9 V
Frequency the DTC runs = Continuously - After the running conditions are met
P178F, P17C4
- Battery Voltage = Greater than 9 V
- Engine Speed = Greater than 500 RPM
- Run/Crank Ignition 1 Voltage = Greater than 9 V
Frequency the DTC runs = Continuously - After the running conditions are met