Conditions for Running the DTC
WARNING: This page is about a different variant/trim than selected.
P0716
- Accelerator Pedal Position = Greater than 5%
- Engine Torque = 30 to 8191 N.m (22 to 6041 lb ft)
- Power Mode Status = Run
- Transmission Input Speed = 160 to 254 RPM
DTC runs continuously when the above conditions are met.
P0717
- Accelerator Pedal Position = Greater than 5%
- Brake Pedal Position Less than 70%
- Engine Torque 30 to 8191 N.m (22 to 6041 lb ft)
- Power Mode Status = Run
- Transmission Input Speed = Greater than 320 RPM
Frequency the DTC runs = Continuously - After the running conditions are met
P07BF, P07C0
- Battery Voltage = Greater than 10 V
- Power Mode Status = Run
- Run/Crank Voltage = Greater than 10 V
Frequency the DTC runs = Continuously - After the running conditions are met