LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2019 >> Cruze Premier, 4D Hatchback >> Repair and Diagnosis >> Brakes >> Mechanical - Hydraulic >> Hydraulic Brakes >> Diagnostic Information and Procedures >> Brake Warning Indicator Malfunction >> Circuit/System Verification

Circuit/System Verification

  1. Verify that the brake fluid has the proper level. The fluid level should be above minimum level.
    • Go to next step: If above minimum level 
  2. Ignition ON.
  3. Verify the scan tool Electronic Brake Control Module, Brake Fluid Level Sensor parameter. The reading should be Ok.
    • If the parameter is Low 

      Refer to Brake Fluid Level Switch Malfunction.

    • Go to next step: If the parameter is Ok 
  4. Verify the scan tool Body Control Module, Park Brake Switch parameter changes between Active and Inactive while applying and releasing the parking brake.
    • If the parameter does not change 

      Refer to Park Brake Switch Malfunction.

    • Go to next step: If the parameter changes 
  5. Verify the brake warning indicator turns ON and OFF, when commanding the instrument cluster All Indicators ON and OFF with a scan tool.
    • If the brake warning indicator does not turn ON and OFF 

      Replace the P16 Instrument Cluster.

    • Go to next step: If the brake warning indicator turns ON and OFF 
  6. All OK.