Circuit/System Verification
- Ignition ON.
- Verify the scan tool Hazard Lamps Switch parameter changes between Active and Inactive while commanding the hazard lamps ON and OFF with the hazard warning switch.
- If the parameter does not change
Refer to Circuit/System Testing.
- Go to next step: If the parameter changes
- If the parameter does not change
- Verify all left and right turn signal lamps turn ON and OFF while commanding the hazard lamps ON and OFF with the hazard warning switch.
- If all turn signal lamps do not turn ON and OFF
- Go to next step: If all turn signal lamps turn ON and OFF
- All OK.