Conditions for Setting the DTC
P0133, P0153, P015A, P015B, P015C or P015D
The ECM detects that the HO2S 1 rich-to-lean or lean-to-rich average response time is greater than a calibrated value for greater than 60s.
P013A or P013C
The ECM detects that the accumulated mass air flow monitored during rich-to-lean transitions between 450 - 150 mV is greater than calibrated value.
P013B or P013D
The ECM detects that the accumulated mass air flow monitored during lean-to-rich transitions between 350 - 650 mV is greater than calibrated value.
P013E or P014A
The ECM detects that the O2 sensor voltage has not decreased below 450 mV within a calibrated value of accumulated air flow.
P013F or P014B
The ECM detects that the O2 sensor voltage has not increased above 350 mV within a calibrated value of accumulated air flow.
P1133 or P1153
The ECM detects that the heated oxygen sensor rich-to-lean counts, or the lean-to-rich counts are less than a calibrated value for greater than 100s.
P2270 or P2272
The ECM does not detect a HO2S voltage greater than 800 mV before accumulated mass air flow exceeds a calibrated value.
P2271 or P2273
The ECM does not detect an HO2S voltage less than 100 mV before accumulated mass air flow exceeds a calibrated value.