LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2018 >> Spark LT, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 67 (HVAC System - Manual) >> Diagnostic Information and Procedures >> HVAC System Malfunction >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2017 Chevrolet Spark. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF and all vehicle systems OFF. It may take up to 2 min for all vehicle systems to power down.
  2. Disconnect the harness connector at the K33 HVAC Control Module.
  3. Test for less than 10 Ω between the ground circuit terminal 8 and ground.
    • If 10 Ω or greater 
    1. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • If less than 10 Ω 
  4. Verify a test lamp illuminates between the B+ circuit terminal 1 and ground.
    • If the test lamp does not illuminate and the circuit fuse is good 
    1. Ignition OFF, remove the test lamp.
    2. Test for less than 2 Ω in the B+ circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
    • If the test lamp does not illuminate and the circuit fuse is open 
    1. Ignition OFF, remove the test lamp.
    2. Test for infinite resistance between the B+ circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the K33 HVAC Control Module.
    • If the test lamp illuminates 
  5. Ignition ON, verify a test lamp illuminates between the ignition circuit terminal 9 and ground.
    • If the test lamp does not illuminate and the circuit fuse is good 
    1. Ignition OFF, remove the test lamp.
    2. Test for less than 2 Ω in the ignition circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, verify the fuse is not open and there is voltage at the fuse.
    • If the test lamp does not illuminate and the circuit fuse is open 
    1. Ignition OFF, remove the test lamp.
    2. Test for infinite resistance between the ignition circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the K33 HVAC Control Module.
    • If the test lamp illuminates 
  6. Replace the K33 HVAC Control Module.