Refrigerant Recovery and Recharging
To remove, recycle and install R-1234yf from/to a vehicles refrigerant system only use GE-50300-A R-1234yf Air Conditioning Refrigerant Recovery/Recharge Cart or refrigerant recovery recharge equipment certified to meet the requirements of SAE J2843.
To remove contaminated refrigerant from a vehicles refrigerant system use GE-50957 Machine R-1234yf Contaminated Refrigerant or only service equipment designed for contaminated refrigerant removal and certified to meet the requirements of SAE J2851. Refrigerant recovered by this equipment cannot be reused or recycled on site and must be sent to an approved reclamation facility for reprocessing or disposal.
To prevent accidental release of refrigerant and minimize safety concerns, the installation of any refrigerant service equipment to the vehicle shall only be done with the engine off and after the refrigerant high side pressure has been reduced (approximately 2 - 3 minutes).
Open the windows and/or doors before charging the vehicle to prevent an accumulation of refrigerant in case of a major refrigerant leak.
Refrigerant service equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide for accurate recharging of mobile air conditioning systems. Venting refrigerant to the atmosphere is illegal in the USA and EU and may have restrictions in other regions.
To protect the refrigerant supply GE-50300-A R-1234yf Air Conditioning Refrigerant Recovery/Recharge Cart or SAE J2843 equipment requires the refrigerant to be analyzed for purity prior to its recovery or transfer. The equipment is required to receive an acceptable reading from the integrated refrigerant identifier prior to recovery or transfer.
If an unacceptable reading is received (and the presence of foreign gases detected) the refrigerant is considered contaminated and the equipment will not allow its recovery or transfer to an onboard storage vessel. If refrigerant is contaminated use GE-50957 Machine R-1234yf Contaminated Refrigerant or SAE J2851 compliant equipment to recover for reclamation and/or disposal at an EPA approved facility (http://www.epa.gov/ozone/title6/608/reclamation/reclist.html) or regional approved facility.
As a safety precaution GE-50300-A R-1234yf Air Conditioning Refrigerant Recovery/Recharge Cart or SAE J2843 compliant equipment requires the MAC system to pass a pre-charge leak test (to detect the possibility of a gross system leak prior to charging, >0.3 g/s) prior to allowing the MAC system to be charged. The pressurized portion of this test will require the technician set the vehicles HVAC blower motor on high, A/C switch off and air distribution mode set to floor. The technician shall insert a GE-50078 Electronic Leak Detector or J2913-compliant electronic leak detector, set to low sensitivity (14 grams/year leak rate) into the center of a floor duct outlet, as far as possible. When the technician confirms that the vehicle is set up for the pressurized leak check the GE-50300-A R-1234yf Air Conditioning Refrigerant Recovery/Recharge Cart will install 15% of the programmed charge into the vehicles refrigerant system. The technician monitors the electronic leak detector for 5 minutes or until the detector alarms.
The equipments display will then ask the following:
- Was this test performed? If the technician replies Yes, the display next shall ask,
- Was a leak found? If technician replies Yes, the machine shall only allow recovery and evacuation to allow repair. If the technician replies No, the display shall continue with,
- Is there an auxiliary evaporator? If the technician replies No the machine shall permit completion of the recharge process. If the technician replies Yes, the display shall instruct the technician to perform a leak check with GE-50078 Electronic Leak Detector or a J2913-compliant detector at a rear evaporator outlet, then ask,
- Was an auxiliary evaporator leak check performed? If the technician replies Yes, the display will continue with Was a leak found? and if the answer is Yes, the machine shall only allow recovery and evacuation to allow repair. If the technician replies No, the machine shall permit completion of the recharge process.